Welcome
Contact Us

Services
Products
Home

revised February 1st, 2001

MEGALENE GAS SYSTEM TREATMENT, now with METALON, is a new and improved hydrocarbon complex that incorporates components which are ashless, non-phophorous, and perform as multi-functional detergents and dispersants. Supplementary to the data below, these proprietary components exceed the Military Specifications MIL-I-25017C, providing excellent rust protection in both leaded and unleaded gasolines.

Extensive engine tests were conducted on 250 CID, 216 CID straight six-cylinder engines as well as 350 CID V-8 and 140 CID four-cylinder engines. Positive results in carburetor and fuel injector detergency, anti-icing, intake valve deposit cycling and octane requirement tests were achieved, respectively.

MEGALENE GAS SYSTEM TREATMENT, with METALON can be added to all gasolines used in internal combustion engines. It is compatible with catalytic converters.

MEGALENE GAS SYSTEM TREATMENT exclusive formulation, used consistently as recommended, helps to:
>LUBRICATE THE UPPER CYLINDER >MAINTAIN OPTIMUM CARBURETOR >NEUTRALIZE ACIDS
  COMPONENTS   AND FUEL INJECTOR PERFORMANCE >IMPROVE COLD WEATHER STARTS
>ENHANCE COMBUSTION >CLEAN PVC SYSTEM >PREVENT FUEL SYSTEM ICING
>CLEAN VARNISH AND GUM RESIDUES >REDUCE BLOW-BY OIL DILUTION >MAINTAIN EMISSION CONTROL
  THROUGHOUT THE FUEL SYSTEM >CONTROL CONDENSATION   SYSTEM EFFICIENCY
>ELIMINATE CARBON DEPOSITS >REDUCE SLUDGE FORMATION >IMPROVE ECONOMY
>FREE STICKY VALVES >PREVENT ENGINE "RUN-ON" >ARREST RUST AND CORROSION

RECOMMENDATIONS: MEGALENE GAS SYSTEM TREATMENT
highly-concentrated formula is very cost-effective. For the first 200 litres ( U.S. gallons) of gasoline, add 20mL (.75 oz.) to every 40L (10gal.) (For rapid results, slowly pour 50mL directly into the carburetor with the engine at fast idle.) Regularly add 10mL for every 40 litres.
CAUTION: MEGALENE is flammable. Keep away from open flame or spark. It contains petroleum distillates. If swallowed, DO NOT induce vomiting. Call a physician immediately.

INSPECTION DATA:
DESCRIPTION ASTM METHOD TEST RESULTS
Specific Gravity @ 60°F D-1298 0.8454
Appearance D-1500 CLEAR
Flash Point °F (Closed Cup) D-93 68
Pour Point °F D-97 -55
Viscosity SUS @ 100 °F D-88 40.0 (4.25 cSt)
Corrosion Test-Copper strip @ 212°F D-139 1a - PASS

NOTE:
The information and data presented herein are based on tests, reports, and research we believe to be accurate and reliable. The information and data are provided without warranty, guarantee or liability on our part, and are therefore, provided to customers for their own investigation, verification, and consideration.

Contact Us / Services / Products

Copyright © 2002 Oil Butler. All Rights Reserved.  Email: rob@oilbutler.ca 